{"id":3405,"date":"2023-01-12T09:37:50","date_gmt":"2023-01-12T09:37:50","guid":{"rendered":"https:\/\/www.as-i.pl\/?p=3405"},"modified":"2023-08-22T09:48:01","modified_gmt":"2023-08-22T09:48:01","slug":"as-interface-safety-at-work-technologia-bezpieczenstwa-niezalezna-od-systemu-nadrzednego","status":"publish","type":"post","link":"https:\/\/www.as-i.pl\/index.php\/2023\/01\/12\/as-interface-safety-at-work-technologia-bezpieczenstwa-niezalezna-od-systemu-nadrzednego\/","title":{"rendered":"AS-Interface Safety At Work &#8211; technologia bezpiecze\u0144stwa niezale\u017cna od systemu nadrz\u0119dnego"},"content":{"rendered":"\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp;<span style=\"color: #000000;\"> &nbsp;Aspekty bezpiecze\u0144stwa odgrywaj\u0105 wa\u017cn\u0105 rol\u0119 w coraz wi\u0119kszej liczbie zautomatyzowanych system\u00f3w sterownia, a szczeg\u00f3lnie tam, gdzie powstaje zagro\u017cenie dla bezpiecze\u0144stwa personelu, wynikaj\u0105ce z niebezpiecznych ruch\u00f3w cz\u0119\u015bci maszyn lub urz\u0105dze\u0144. Wymagania dotycz\u0105ce bezpiecze\u0144stwa maszyn i urz\u0105dze\u0144 s\u0105 oczywi\u015bcie \u015bci\u015ble okre\u015blone i udokumentowane np. w dyrektywie maszynowej UE (dyrektywa 2006\/42\/WE), jak r\u00f3wnie\u017c w lokalnych przepisach dotycz\u0105cych bezpiecze\u0144stwa pracy w r\u00f3\u017cnych krajach.<\/span><br><span style=\"color: #000000;\">&nbsp; &nbsp; &nbsp;Podobnie jak sama technologia ASi, r\u00f3wnie\u017c i opracowanie technicznych i technologicznych podstaw funkcjonalno\u015bci ASi Safety At Work by\u0142o wynikiem wsp\u00f3\u0142pracy kilku firm, kt\u00f3re stworzy\u0142y konsorcjum: ASi Safety At Work Consortium. Same za\u0142o\u017cenia jakie przy\u015bwieca\u0142y pracom nad implementacja bezpiecze\u0144stwa w ASi jasno okre\u015bla\u0142y, \u017ce nowa funkcjonalno\u015b\u0107 musi by\u0107 mo\u017cliwa do adaptacji w ju\u017c istniej\u0105cych systemach. Tym samym warunkiem konicznym by\u0142o utrzymanie sposobu komunikacji, bez \u017cadnej ingerencji m.in. w budow\u0119 samych telegram\u00f3w. <\/span><\/p>\n\n\n\n<div style=\"height:18px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">ASi Safety, a wi\u0119c bezpiecze\u0144stwo niezale\u017cne od nadrz\u0119dnego systemu sterowania<\/h2>\n\n\n\n<div style=\"height:18px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp; &nbsp; <span style=\"color: #000000;\">Patrz\u0105c \u015bci\u015ble funkcjonalnie mo\u017cna powiedzie\u0107, \u017ce realizacja zada\u0144 bezpiecze\u0144stwa z wykorzystaniem interfejsu ASi jest podobna do standardowego systemu okablowania, gdzie wszystkie urz\u0105dzenia bezpiecze\u0144stwa s\u0105 \u0142\u0105czone w osobnym obwodzie, nie maj\u0105c \u017cadnego wp\u0142ywu na budow\u0119 czy te\u017c prac\u0119 systemu wymiany danych standardowych. Ale to podobie\u0144stwo dotyczy tylko samej funkcji &#8211; w ka\u017cdym innym aspekcie <strong>ASi Safety At Work jest kompletnie inne ni\u017c systemu r\u00f3wnoleg\u0142e. <\/strong><\/span><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/ASiSaW.png\" alt=\"\" class=\"wp-image-3406\" style=\"width:500px;height:354px\" width=\"500\" height=\"354\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/ASiSaW.png 1000w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/ASiSaW-300x212.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/ASiSaW-768x543.png 768w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:27px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp;<span style=\"color: #000000;\"> &nbsp; Ka\u017cdy system ASi charakteryzuje si\u0119 wykorzystaniem prostego, nieekranowanego, dwu\u017cy\u0142owego przewodu stanowi\u0105cego g\u0142\u00f3wn\u0105 magistral\u0119 interfejsu. Jest to technologia \u0142atwa w obs\u0142udze, pozwalaj\u0105ca unikn\u0105\u0107 b\u0142\u0119d\u00f3w pod\u0142\u0105cze\u0144 podczas instalacji i zapewniaj\u0105ca najlepszy mo\u017cliwy poziom elastyczno\u015bci przy rozbudowie. <strong>W odniesieniu do nadrz\u0119dnych system\u00f3w sterowania, technologia oparta na AS-Interface jest ca\u0142kowicie niezale\u017cna.<\/strong> Oznacza to, \u017ce mo\u017ce by\u0107 stosowana z ka\u017cdym i dowolnym interfejsem sterowania nadrz\u0119dnego z wykorzystaniem odpowiedniej bramki (Gateway). Jest to cecha charakterystyczna ASi, gwarantuj\u0105ca mo\u017cliwo\u015b\u0107 skorzystania z tego rozwi\u0105zania z ka\u017cdym sterownikiem wy\u017cszego poziomu, niezale\u017cnie od wspieranego interfejsu czy te\u017c producenta. Samo uruchomienie jest niezwykle proste i szybkie, co czyli ten system szczeg\u00f3lnie wydajnym w odniesieniu do koszt\u00f3w ca\u0142o\u015bciowych projektu danej instalacji. <\/span><\/p>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"215\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/interfaces-1024x215.png\" alt=\"\" class=\"wp-image-3408\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/interfaces-1024x215.png 1024w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/interfaces-300x63.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/interfaces-768x161.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/interfaces.png 1500w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>ASi jest odpowiednim systemem komunikacyjnym dla ka\u017cdego sterownika PLC.<\/strong><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:46px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Jedna z najprostszych koncepcji instalacyjnych na \u015bwiecie<\/strong><\/h2>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp; <span style=\"color: #000000;\">&nbsp;W przypadku konwencjonalnego okablowania r\u00f3wnoleg\u0142ego do osi\u0105gni\u0119cia PLe potrzebne s\u0105 co najmniej cztery linie na wy\u0142\u0105cznik typu E-STOP, plus dodatkowe dwie linie przewodowe dla wska\u017anika stanu urz\u0105dzenia (np. wska\u017anik LED). W przypadku innych urz\u0105dze\u0144 bezpiecze\u0144stwa, np. z wyj\u015bciami OSSD a nie stykami beznapi\u0119ciowymi, tych dodatkowych przewod\u00f3w mo\u017ce by\u0107 jeszcze wi\u0119cej.<\/span><\/p>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">&nbsp; &nbsp; &nbsp;Natomiast dzi\u0119ki technologi ASi Safety At Work, z jakiej korzystaj\u0105 urz\u0105dzenia bezpiecze\u0144stwa Bihl+Wiedemann, mo\u017cliwa jest transmisja do 62 sygna\u0142\u00f3w bezpiecznych z wykorzystaniem tylko<span class=\"Apple-converted-space\">&nbsp; <\/span>jednego przewodu 2-\u017cy\u0142owego, kt\u00f3ry dodatkowo dostarcza do nich zasilanie. Co jest r\u00f3wnie\u017c bardzo istotne to szczeg\u00f3\u0142owa i dok\u0142adna diagnostyka. W tym przypadku awarii jakiegokolwiek z urz\u0105dze\u0144 informacja jest natychmiastowo wy\u015bwietlana na wy\u015bwietlaczu Mastera ASi oraz przesy\u0142ana, w obrazie danych diagnostycznych, do sterownika nadrz\u0119dnego,. Tak szybka detekcja b\u0142\u0119du\/uszkodzenia nie jest mo\u017cliwa w przypadku szeregowego \u0142\u0105czenia wy\u0142\u0105cznik\u00f3w bezpiecze\u0144stwa (niezale\u017cnie od technologii), z kt\u00f3rego instalatorzy cz\u0119sto korzystaj\u0105 w celu zmniejszenia ilo\u015bci przewod\u00f3w i koszt\u00f3w instalacji.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/span><\/p>\n\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3><span style=\"color: #000000;\"><b>Wynikiem zastosowania ASi jest:<\/b><\/span><\/h3>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Znacznie uproszczone okablowanie &#8211; widoczna oszcz\u0119dno\u015b\u0107 koszt\u00f3w<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Mo\u017cliwo\u015b\u0107 przeprowadzenia wst\u0119pnego monta\u017cu<\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Znacznie zmniejszona podatno\u015b\u0107 na b\u0142\u0119dy ni\u017c w przypadku konwencjonalnego okablowania r\u00f3wnoleg\u0142ego<\/span><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab.png\" alt=\"\" class=\"wp-image-2382\" style=\"width:256px;height:256px\" width=\"256\" height=\"256\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab.png 512w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab-300x300.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab-150x150.png 150w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab-270x270.png 270w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab-192x192.png 192w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab-180x180.png 180w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2022\/03\/cropped-logo_tab-32x32.png 32w\" sizes=\"auto, (max-width: 256px) 100vw, 256px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">&nbsp; &nbsp; &nbsp;Jak wspomniano wcze\u015bniej, koncepcja Safety at Work umo\u017cliwia bezproblemow\u0105 integracj\u0119 komponent\u00f3w bezpiecze\u0144stwa, tj. czujnik\u00f3w bezpiecze\u0144stwa i element\u00f3w wykonawczych, jak r\u00f3wnie\u017c monitor\u00f3w bezpiecze\u0144stwa, z praktycznie ka\u017cdym powszechnie stosowanym systemem automatyki. W por\u00f3wnaniu z konwencjonalnymi rozwi\u0105zaniami bezpiecze\u0144stwa, bardzo istotn\u0105 zalet\u0105 ASi Safety at Work jest mo\u017cliwo\u015b\u0107 przesy\u0142ania <b>sygna\u0142\u00f3w bezpiecznych i standardowych za pomoc\u0105 tego samego przewodu<\/b>. Eliminuje to wymagan\u0105 wcze\u015bniej redundantn\u0105 infrastruktur\u0119, a tak\u017ce znacznie obni\u017ca koszty zwi\u0105zane ze skomplikowanym i podatnym na b\u0142\u0119dy okablowaniem r\u00f3wnoleg\u0142ym.<\/span><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"735\" height=\"1024\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/conventional-735x1024.png\" alt=\"\" class=\"wp-image-3424\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/conventional-735x1024.png 735w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/conventional-215x300.png 215w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/conventional-768x1070.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/conventional-1102x1536.png 1102w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/conventional.png 1435w\" sizes=\"auto, (max-width: 735px) 100vw, 735px\" \/><\/figure>\n<\/div>\n\n\n<p style=\"text-align: center;\"><em><span style=\"color: #000000;\">Okablowanie standardowe<\/span><\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"731\" height=\"1024\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_no_safety-731x1024.png\" alt=\"\" class=\"wp-image-3425\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_no_safety-731x1024.png 731w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_no_safety-214x300.png 214w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_no_safety-768x1076.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_no_safety-1097x1536.png 1097w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_no_safety.png 1428w\" sizes=\"auto, (max-width: 731px) 100vw, 731px\" \/><\/figure>\n<\/div>\n\n\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><em>System AS-Interface bez obs\u0142ugi systemu bezpiecze\u0144stwa<span class=\"Apple-converted-space\">&nbsp;<\/span><\/em><\/span><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"707\" height=\"1024\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_complete-707x1024.png\" alt=\"\" class=\"wp-image-3423\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_complete-707x1024.png 707w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_complete-207x300.png 207w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_complete-768x1113.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_complete-1060x1536.png 1060w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/asi_complete.png 1380w\" sizes=\"auto, (max-width: 707px) 100vw, 707px\" \/><\/figure>\n<\/div>\n\n\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><em>Pe\u0142ny system AS-Interface i ASi Safety At Work<\/em><\/span><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp; &nbsp;<span style=\"color: #000000;\"> Elementy bezpiecze\u0144stwa ASi mog\u0105 by\u0107 instalowane tak jak ka\u017cdy inny modu\u0142 w dowolnym miejscu sieci ASi, w po\u0142\u0105czeniu ze standardowymi modu\u0142ami ASi oraz bez \u017cadnych ogranicze\u0144 i restrykcji. Master ASi traktuje komponenty bezpiecze\u0144stwa tak samo jak ka\u017cdy inny normalny modu\u0142 ASi, natomiast wszystkie urz\u0105dzenia realizuj\u0105ce funkcje zabezpieczenia (czujniki bezpiecze\u0144stwa, aktuatory bezpiecze\u0144stwa, monitor bezpiecze\u0144stwa) wsp\u00f3\u0142dzia\u0142aj\u0105 dodatkowo korzystaj\u0105c ze specjalnego \u015brodowiska komunikacyjnego.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><b>ASi Safety at Work jest zatwierdzony dla aplikacji z wymaganiami bezpiecze\u0144stwa do SIL3 zgodnie z EN 61508 lub PLe zgodnie z EN ISO 13 849-1:2006.<\/b><\/span><\/p>\n\n\n\n<div style=\"height:29px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">&nbsp; &nbsp; &nbsp;Poniewa\u017c w dalszym ci\u0105gu jest to technologia AS-Interface to obowi\u0105zuj\u0105 te same zalety jakie w przypadku standardowego systemu sterownia opartego na ASi (wi\u0119cej <strong><span style=\"color: #333399;\"><a style=\"color: #333399;\" href=\"https:\/\/www.as-i.pl\/index.php\/2021\/03\/23\/co-to-jest-as-interface-2\/\" target=\"_blank\" rel=\"noopener\">TUTAJ<\/a><\/span><\/strong>).<span class=\"Apple-converted-space\">&nbsp;<\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Tylko jeden, nieekranowany, 2-\u017cy\u0142owy przew\u00f3d ASi.<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Dane i zasilanie na tym samym przewodzie<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Technologia Piercing znacznie u\u0142atwiaj\u0105ca instalacj\u0119<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Mo\u017cliwo\u015b\u0107 pod\u0142\u0105czenia do 62 podrz\u0119dnych urz\u0105dze\u0144 bezpiecze\u0144stwa<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Brak ogranicze\u0144 topologicznych<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Bardzo prosta rozbudowa istniej\u0105cej instalacji<\/span><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2021\/03\/installation.png\" alt=\"\" class=\"wp-image-1947\" style=\"width:402px;height:162px\" width=\"402\" height=\"162\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2021\/03\/installation.png 1000w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2021\/03\/installation-300x121.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2021\/03\/installation-768x310.png 768w\" sizes=\"auto, (max-width: 402px) 100vw, 402px\" \/><\/figure>\n<\/div>\n\n\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><em>Technologia Piercing<\/em><\/span><\/p>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/Articles\/Cable\/free_topology.png\" alt=\"\" class=\"wp-image-933\" style=\"width:390px;height:247px\" width=\"390\" height=\"247\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/Articles\/Cable\/free_topology.png 630w, https:\/\/www.as-i.pl\/wp-content\/uploads\/Articles\/Cable\/free_topology-300x190.png 300w\" sizes=\"auto, (max-width: 390px) 100vw, 390px\" \/><\/figure>\n<\/div>\n\n\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><em>Swobodny wyb\u00f3r topologii<\/em><\/span><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Prosta technologia instalacji<\/strong><\/h2>\n\n\n\n<div style=\"height:22px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p style=\"text-align: justify;\">&nbsp; &nbsp; &nbsp;<span style=\"color: #000000;\">AS-Interface korzysta z bardzo prostej technologii przebijania (piercing), na kt\u00f3rej zastosowanie pozwala profilowy przew\u00f3d ASi. Wystarczy w\u0142o\u017cy\u0107 przew\u00f3d w odpowiednie korytka monta\u017cowe podstawy modu\u0142u i dokr\u0119ci\u0107 sam modu\u0142 &#8211; na tym monta\u017c elektryczno-mechaniczny si\u0119 ko\u0144czy. Ig\u0142y kontaktowe modu\u0142y zawsze przechodz\u0105 przez izolacj\u0119 przewodu ASI w pionie, co gwarantuje doskona\u0142y kontakt z ka\u017cd\u0105 z \u017cy\u0142 (4 lub 6 pin\u00f3w na modu\u0142 i 2 lub 3 piny na \u017cy\u0142\u0119). Co wi\u0119cej, specjalny profil przewodu umo\u017cliwia monta\u017c tylko w jednej pozycji, gwarantuj\u0105c tym samym ochron\u0119 przed odwr\u00f3ceniem polaryzacji podczas instalacji.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/span><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/csm_Montagetechnik_a0e992f62e-1024x416.png\" alt=\"\" class=\"wp-image-3437\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/csm_Montagetechnik_a0e992f62e-1024x416.png 1024w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/csm_Montagetechnik_a0e992f62e-300x122.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/csm_Montagetechnik_a0e992f62e-768x312.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/csm_Montagetechnik_a0e992f62e.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Odci\u0105\u017cenie nadrz\u0119dnej magistrali sieciowej<\/strong><\/h2>\n\n\n\n<div style=\"height:22px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp; &nbsp;<span style=\"color: #000000;\"> Technologia bezpiecze\u0144stwa, kt\u00f3ra jest ca\u0142kowicie niezale\u017cna od sterownika PLC znacznie odci\u0105\u017ca sterownik wy\u017cszego poziomu: zamiast wielu indywidualnych sieciowych urz\u0105dze\u0144 podrz\u0119dnych do g\u0142\u00f3wnej magistrali jest pod\u0142\u0105czona tylko bramka bezpiecze\u0144stwa. Bramka zbiera wszystkie sygna\u0142y i udost\u0119pnia sieci nadrz\u0119dnej.<\/span><\/p>\n\n\n\n<div style=\"height:22px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"775\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_1-1024x775.png\" alt=\"\" class=\"wp-image-3439\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_1-1024x775.png 1024w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_1-300x227.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_1-768x581.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_1.png 1500w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:22px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">&nbsp; &nbsp; &nbsp;Poza odci\u0105\u017ceniem sterownika, zastosowanie takiego rozwi\u0105zania umo\u017cliwia bardziej kompaktow\u0105 budow\u0119 maszyn, poniewa\u017c zapewnia znaczn\u0105 oszcz\u0119dno\u015b\u0107 miejsca w szafach sterowniczych zdecentralizowanego uk\u0142adu zautomatyzowanego. W odniesieniu do instalacji polowych technika monta\u017cu jest zawsze taka sama i eliminuje konieczno\u015b\u0107 korzystania z jakichkolwiek drogich z\u0142\u0105cz, wtyk\u00f3w czy te\u017c konwerter\u00f3w. Poprawiona zostaje te\u017c przejrzysto\u015b\u0107 ca\u0142ej instalacji i znacznie zwi\u0119kszona wydajno\u015b\u0107 nadrz\u0119dnej magistrali sterowania.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/span><\/p>\n\n\n\n<div style=\"height:27px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Swobodny wyb\u00f3r czujnik\u00f3w i element\u00f3w wykonawczych<\/strong><\/h2>\n\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp; &nbsp; <span style=\"color: #000000;\">Je\u017celi np. w danym systemie skorzystano z wielu kurtyn bezpiecze\u0144stwa producenta X oraz wielu wy\u0142\u0105cznik\u00f3w drzwiowych z blokad\u0105 firmy Y , to konwencjonalna instalacja wymaga, aby wszystkie sygna\u0142y (\u0142\u0105cznie ze zwolnieniem czy restartem) by\u0142y po\u0142\u0105czone do osobnych wej\u015b\u0107\/wyj\u015b\u0107 systemu w szafie sterowniczej. Takie podej\u015bcie wydatnie zwi\u0119ksza nie tylko koszt jednostkowy, przypadaj\u0105cy na dany sygna\u0142, ale r\u00f3wnie\u017c czas instalacji i koszt samego okablowania. Co wi\u0119cej, takie podej\u015bcie jest jednocze\u015bnie bardzo podatne na b\u0142\u0119dy monta\u017cowe i \u0142\u0105czeniowe.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/span><\/p>\n\n\n\n<p style=\"text-align: justify;\">&nbsp; &nbsp; &nbsp; <span style=\"color: #000000;\">Skorzystanie z rozwi\u0105zania bazuj\u0105cego na AS-Interface znacznie u\u0142atwia nie tylko instalacj\u0119, ale r\u00f3wnie\u017c etap projektowania i uruchomienia takiej instalacji. Skorzystanie z tzw. Aktywnych Dystrybutor\u00f3w Bezpiecze\u0144stwa (inne wykonanie mechaniczne standardowych modu\u0142\u00f3w bezpiecze\u0144stwa) pozwala na swobodne \u0142\u0105czenie urz\u0105dze\u0144 r\u00f3\u017cnych producent\u00f3w do jednej magistrali. Poza rozwi\u0105zaniami uniwersalnymi, przeznaczonych dla urz\u0105dze\u0144 standardowych, w ofercie Bihl+Wiedemann znajduje si\u0119 wiele modu\u0142\u00f3w dedykowanych do wsp\u00f3\u0142pracy z okre\u015blonymi wy\u0142\u0105cznikami, blokadami itp. Ta dedykacja polega na specjalnym wykorzystaniu dost\u0119pnych w ASi bit\u00f3w danych i bit\u00f3w parametr\u00f3w do bezproblemowej obs\u0142ugi urz\u0105dze\u0144 bezpiecze\u0144stwa i, dla przyk\u0142adu, zwolnienia blokady danego zamka bez konieczno\u015bci \u0142\u0105czenia danego sygna\u0142u do osobnego wyj\u015bcia systemowego.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/span><\/p>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">Dzi\u0119ki <strong><span style=\"color: #000080;\"><a style=\"color: #000080;\" href=\"https:\/\/www.bihl-wiedemann.de\/eu\/products\/safety-components\/active-distributors-asi-safety\/product-selector-active-distributors-asi-safety\" target=\"_blank\" rel=\"noopener\">aktywnym rozdzielaczom&nbsp;firmy Bihl+Wiedemann<\/a><\/span><\/strong> mo\u017cna w prosty spos\u00f3b zintegrowa\u0107 w sieci ASi wszystkie czujniki i elementy wykonawcze <b>niezale\u017cnie od producenta:<\/b><\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Wy\u0142\u0105czniki bezpiecze\u0144stwa<\/span><br><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Czujniki bezpiecze\u0144stwa<\/span><br><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Wy\u0142\u0105czniki drzwiowe z blokad\u0105<\/span><br><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Optoelektroniczne urz\u0105dzenia ochronne<\/span><br><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Wy\u0142\u0105czniki E-STOP<\/span><\/p>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">&nbsp; &nbsp; &nbsp;Aktywne rozdzielacze firmy Bihl+Wiedemann umo\u017cliwiaj\u0105 pod\u0142\u0105czenie czujnik\u00f3w i element\u00f3w wykonawczych bezpo\u015brednio w tym miejscu gdzie s\u0105 one wymagane, zachowuj\u0105c stopie\u0144 szczelno\u015bci IP67. Takie elastyczne podej\u015bcie zapewnia wiele korzy\u015bci od procesu projektowania do utrzymania i ewentualnej p\u00f3\u017aniejszej rozbudowy.<span class=\"Apple-converted-space\">&nbsp;<\/span><\/span><\/p>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"391\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_2-1024x391.png\" alt=\"\" class=\"wp-image-3444\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_2-1024x391.png 1024w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_2-300x115.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_2-768x293.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_2.png 1500w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:85px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Proste sterowanie i uruchomienie niezale\u017cnie od sterownika nadrz\u0119dnego<\/strong><\/h2>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"673\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_3-1024x673.png\" alt=\"\" class=\"wp-image-3446\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_3-1024x673.png 1024w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_3-300x197.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_3-768x505.png 768w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Safety_3.png 1500w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:36px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">System bezpiecze\u0144stwa oparty na ASi Safety At Work mo\u017ce zosta\u0107 uruchomiony niezale\u017cnie od sterownika wy\u017cszego poziomu:<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Brak z\u0142\u0105czy monta\u017cowych &#8211; prostota instalacji do poziomu czujnik\u00f3w<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Zintegrowana diagnostyka fizyczna i logiczna<\/span><\/p>\n<p><span style=\"color: #000000;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1416\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2020\/10\/green_marker.png\" alt=\"\" width=\"20\" height=\"20\">&nbsp;&nbsp;Nie s\u0105 wymagane dodatkowe urz\u0105dzenia pomiarowe<\/span><\/p>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">\u00a0 \u00a0 \u00a0 Dodatkowa funkcjonalno\u015b\u0107 (opisana w innym artykule) naszych urz\u0105dze\u0144 to mo\u017cliwo\u015b\u0107 dzielenia sygna\u0142\u00f3w bezpiecze\u0144stwa pomi\u0119dzy r\u00f3\u017cnymi monitorami bezpiecze\u0144stwa, z wykorzystaniem opatentowanej technologii zwanej <b>Safe Link<\/b>.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">\u00a0 \u00a0 \u00a0 Dodatkowo nale\u017cy pami\u0119ta\u0107, \u017ce nasze bramki ASi ze zintegrowanym Monitorem Bezpiecze\u0144stwa mog\u0105 by\u0107 wyposa\u017cone w interfejsy Safety, jak ProfiSAFE, CIP Safety, itd. W takim przypadku program logiczny odpowiedzialny za realizacje funkcji zabezpieczenia mo\u017ce by\u0107 wykonywany przez sterownik nadrz\u0119dny, a oprogramowanie ASIMON360 pozwala na automatyczne stworzenie zale\u017cno\u015bci pomi\u0119dzy elementami ASi (modu\u0142ami, wy\u0142\u0105cznikami, itd.) a zmiennymi np. ProfiSAFE. Ta automatycznie generowana tablica mo\u017ce by\u0107 nast\u0119pnie wyeksportowana do pliku Excel i zaimportowana do \u015brodowiska programistycznego systemu nadrz\u0119dnego (jak np. TIA Portal).<\/span><\/p>\n\n\n\n<div style=\"height:37px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/08\/Safety_Infosheet.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Brief_graph_PLC_Indep.png\" alt=\"\" class=\"wp-image-3451\" style=\"width:750px;height:215px\" width=\"750\" height=\"215\" srcset=\"https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Brief_graph_PLC_Indep.png 1000w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Brief_graph_PLC_Indep-300x86.png 300w, https:\/\/www.as-i.pl\/wp-content\/uploads\/2023\/01\/Brief_graph_PLC_Indep-768x220.png 768w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; &nbsp; &nbsp;Aspekty bezpiecze\u0144stwa odgrywaj\u0105 wa\u017cn\u0105 rol\u0119 w coraz wi\u0119kszej liczbie zautomatyzowanych system\u00f3w sterownia, a szczeg\u00f3lnie tam, gdzie powstaje zagro\u017cenie dla bezpiecze\u0144stwa personelu, wynikaj\u0105ce z niebezpiecznych ruch\u00f3w cz\u0119\u015bci maszyn lub urz\u0105dze\u0144. Wymagania dotycz\u0105ce bezpiecze\u0144stwa maszyn i urz\u0105dze\u0144 s\u0105 oczywi\u015bcie \u015bci\u015ble okre\u015blone i udokumentowane np. w dyrektywie maszynowej UE (dyrektywa 2006\/42\/WE), jak r\u00f3wnie\u017c w lokalnych przepisach [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3464,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[17,29],"tags":[],"class_list":["post-3405","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artykuly","category-safety"],"_links":{"self":[{"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/posts\/3405","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/comments?post=3405"}],"version-history":[{"count":36,"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/posts\/3405\/revisions"}],"predecessor-version":[{"id":3629,"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/posts\/3405\/revisions\/3629"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/media\/3464"}],"wp:attachment":[{"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/media?parent=3405"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/categories?post=3405"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.as-i.pl\/index.php\/wp-json\/wp\/v2\/tags?post=3405"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}